Installation, repair, and service for wall-mounted split AC units of all major brands in Sharjah.
Air-Con.ae installs, repairs, and services wall-split air conditioners in Sharjah. That includes inverter units that show an error code and older fixed-speed units that only need a capacitor. A written quote comes before parts. Air-Con.ae is the marketing name of Burj Al Qasimiah AC units fix cont.
Airflow, power, and the part that is actually failing.
One written price before any part is fitted.
The unit is run until the supply air and the drain are right.
Wall-split units are the machines we see most in Sharjah apartments and the extra rooms of villas. They fail in a short list of ways: the capacitor, the drain, the flare, the fan, and, on inverters, a sensor or a board. Air-Con.ae, the marketing name of Burj Al Qasimiah AC units fix cont., installs, repairs, and services wall splits across Sharjah. A service and filter clean is typically AED 120 to AED 180. A repair with common parts is typically AED 150 to AED 500. New installation labour starts from AED 350 and is described in full on the installation page. A written quote comes before parts.

The outdoor compressor is not starting. On a fixed-speed Gree or O General unit the run capacitor is the first test. A bulged capacitor or one that reads well below its rating is replaced with the same value. On a Daikin or LG inverter the display code is read before anyone buys a board. A sensor fault, a communication fault, and a dead compressor are different parts and different prices. The code decides which conversation we have.
The drain hose behind the casing is kinked, the fall is wrong, or the pan is blocked with jelly. Al Nahda and Al Majaz units often drain to a short balcony spout that has been flattened. We clear it, reset the fall, and pour water through the pan with the cover off. A pump is fitted only if the outlet is above the unit. Gas does not pour onto the skirting.
The coil ices because the filter and wheel are choked or the charge is low. When the ice melts it looks like a drain leak. We check the filter and the wheel first. If airflow is normal, we leak-test the flares. Roof flares on villas and indoor flares behind apartment units are the usual points. The refill itself is on the gas refill page and is not done while the system is still leaking.
A full drain pan opens the float switch and the unit looks dead. The indoor fuse, the outdoor isolator, and the display receiver are next. We test those before a new remote is sold. A receiver that has taken a drip from the pan is dried and tested. Many “dead remotes” are a wet board.
The fan blade is touching the casing, the motor bearing is dry, or the bracket is loose on the ledge. Vibration through the block wall of a bedroom is often the copper clamped tight, not a failing compressor. We fix the blade, the motor, or the clamp that is actually noisy. A compressor is quoted only after an electrical test.
An instant trip is a short. A trip after the unit has run is often high current from a weak capacitor or a compressor that is overheating. We measure current against the nameplate. Resetting the breaker through the evening burns the terminal. If the compressor winding is gone, we say whether a repair or a new split is the better spend. We do not convert an old R22 machine to R410A.
The outdoor unit is in a shaft or against a wall and is re-breathing its own hot air, or the coil is packed with dust. Al Qasimia and Industrial Area ledges do this. We wash the coil and look at the air path. If the niche is the problem, a clean will help for a while and the location still needs air. That is said plainly.
Relocation is a split job. Refrigerant is pumped down or recovered, the bracket moves, and the lines are vacuumed again. The price follows the new pipe length. Stretching the old pipe around a new wardrobe without a vacuum is how the flare leaks the following month.

Daikin, LG, Samsung, Carrier, Mitsubishi, Gree, Toshiba, O General, Midea, TCL, Haier, and Super General are routine in Sharjah. Fixed-speed units are capacitor, contactor, fan, and flare. Inverters add sensors and boards that must match the model. We copy the model sticker. If you can send a photo of it when you book, the part is more likely to be on the van or ordered the same day rather than after a second visit.
We test indoor power, outdoor power, and the float switch. Airflow before gauges. One written price for the fault found. The room is checked for supply temperature before we leave. A service visit that finds a dead capacitor becomes a repair and is priced as the repair, not as a service plus a surprise. You approve it before the part is fitted.
Al Nahda, Al Majaz, and Al Qasimia are ledge or balcony units. Tell us if the outdoor machine is behind a locked door. Villas in Muwaileh, Al Khan, and Al Taawun add a roof split for the majlis. That flare sees full sun and is the first leak we check. University City flats are the same wall splits as Al Nahda. Shops want the unit high. A cassette in a shop is not a wall split. It is booked as commercial or central work if it is part of a larger system.
Smell and weak air with a compressor that still runs well is cleaning. A unit you want kept that way is maintenance. A failure after midnight is emergency repair. Call +971 50 257 5128 with the area and the symptom. A photo of the model plate saves a trip for the wrong board.
A split is a simple machine until the cheap part is ignored. A capacitor that is left buzzing cooks the compressor terminals. A drain that is wiped at the wall and not cleared inside the casing stains the blockwork and swells the cabinet. A flare that weeps oil, the dark stain at the nut, is a leak you can see without gauges. We point these out on a service visit so they are a choice, not a surprise. You can defer a stained nut. You should not defer a capacitor that is already out of range. The invoice separates them.
If the flat has two splits and only one is weak, do not assume they share a fault. They do not share refrigerant. They might share a breaker. We check the isolator for each outdoor unit because a tripped breaker on the balcony is a frequent “dead split” in Al Majaz. The indoor unit still shows a light from the other circuit and the outdoor unit is silent. That is a switch, not a compressor. Look before you approve a major part. We will show you the silent unit and the live one so the choice is obvious. A photo of the outdoor nameplate, sent before we arrive, is the difference between a capacitor we carry and a board we have to order. The plate is usually on the side panel, not on the fan grille.
| Work | Guide price |
|---|---|
| Split service and filter clean | AED 120–180 |
| Split repair with common parts | AED 150–500 |
| New split installation labour | From AED 350 |
These are guide prices for Sharjah. The technician confirms the exact cost in writing after inspecting the unit. No parts are fitted before you approve the quote.